LCD DC Power Meter 100v - 100A
Product features
Voltage test range: DC 6.5~100V; Current test range: 0~100A
Store energy data when power off(can be reset to 0). The blue backlight can be turned on/off manually
With overload alarm function(If active power is larger than threshold, backlight and power will flash)
Large-screen LCD (display voltage, current, active power, energy at the same time)
Note: only display and shunt are included. It doesn't include any wire or accessories
Main Specifications:
Working voltage: DC 6.5 ~ 100V
Measuring Accuracy: 1%
Power Consumption: 0.2W
Measurement speed: 2 times/s
Store Energy data when power off. Can be reset to 0.
The blue backlight can be turned on/off manually
Test Range and Display format:
1.Active Power test range: 0~10kW
2.Energy test range: 0~9999kWh
3.Voltage test range: DC 6.5~100V
4.Current test range: 0~ 100A
Precautions
1. This module is only suitable for 6.5~100V DC power.
2. Applied load should not exceed the rated power.
3. Wiring order cannot be wrong.
4. This module is suitable for indoor, please do not use outdoor.
Package Include:
1Pcs x DC 6.5-100V 100A Power Multimeter
1Pcs x 100A Shunt
Product Picture

I. Display Interface
Display interface is large-screen LCD, it can display voltage, current, power, energy parameters at the same time.
II. Display format
1. Power: test range: 0~10kW
within 1KW, the display format is 0.0~999.9W;
1KW and above, the display format is 1000~9999W.
2. Energy: test range: 0~9999kWh
Within 10KWh, the display format is 0~9999Wh;
10kWh and above, the display format is 10~9999kWh.
3. Voltage: test range: 6.5~100V
Display format: 6.50~99.99V
4. Current: test range: 0~100A
Display format: 0.00~99.99
III. Key
1. Backlight control
Short press the key to turn on or off the backlight, the backlight has memory function, it can store the on or off state when power off.
2. Reset energy
Step1: Long press the key until the power display area display “CLr”, then release the key.
Step2: At this moment, the energy is flashing to prompt this is the energy reset state, if short press the key again, then the energy value is cleared and exit the reset flashing state.
Step 3: If there is no operation within 5 seconds, it means the energy value is not cleared and will exit the reset state.
3. Set voltage alarm threshold
Step1: Long press the key until the power display area display “SET”, then release the key.
Step2: After enter this state, the voltage area display the current high voltage alarm value, the current area display the current low voltage alarm value and the last digit begin to flash, then you can short press to plus 1, when there is no operation over 3 seconds, it will switch the digit position automatically, from the high
voltage alarm value to the low voltage alarm value, there are total six digits, the range of the voltage alarm threshold is6.5~99.9V;
Step3: After finish the setting, long press the key until the screen display “PASS”, that means you set successfully and will exit the setting state automatically.
4. Choose measuring range
Step 1: Long press the key until the power area display “Curr”, then release the key
Step 2: At this moment, the current area display “100A”, short press the key to switch between“100A”and “50A”, to prompt the range of the external shunt is 100A/75mV or 50A/75mV, please note that this meter can only use these two specification shunt.
Step 3: Long press the key to exit the setting state or after no operation within 3 seconds it will store automatically and exit the setting state.